      EHV50 Series Load Sensitive Multi-way Valve

      Summary

      Closed center for variable pump systems

      Rated pressure: 375 bar

      Rated flow: 500 L/min

      Open All | Close All

      Serial Advantage

      · High efficiency

      · Precise flow control

      · Low pressure loss, saving fuel consumption

      · Good control

      Technical Specification

      General
      StructureMonoblock,Load sensing
      PortInlet port PSAE 1 1/4"-H(ISO 6162)M14
      Work port A1, B1, A2, B2SAE 1"-H(ISO 6162)M12
      Tank port TSAE 1 1/2"-S(ISO 6162)M12
      Pilot inlet port PS
      Pilot tank port D
      M14x1.5(ISO-9974-1)
      Port LSM14x1.5(ISO-9974-1)
      Pressure measurement port
      MA1,MB1,MA2,MB2
      M14x1.5(ISO-9974-1)
      Additional inlet port AP
      Pressure measurement port MT
      3/4-16 UNF
      Additional port AA2,AB21 1/16-12 UN
      Weight kg95
      Hydraulic
      pressureInlet portP(bar)375
      Work portA/B(bar)400
      Tank portT(bar)20
      Drain line pressureD(bar)1
      FlowFrom inlet to working portl/min500
      From working port to tankl/min1000
      Electric
      · Electrical on/of:
      ·Connection:Deutsch DT04-2P
      ·Protection class: IP69k 
      ··Supply voltage:12 or 24VDC
      ·Electrical proportional:
      ·Dither frequency required:100-200Hz
      ·Hysteresis: Less than 3%(at valid range)
      ·Connection:Deutsch DT04-2P/AMP Junior Timer
      ·Protection class:IP69k
      ·Control current @12VDC:0~1500mA;
      @24VDC:0~750mA
      Using environment
      Hydraulic fluidMineral oil (HL, HLP) according to DIN 51524. Other hydraulic fluids, such as HEES (Synthetic Ester) according to VDMA 24568.
      Pressure fluid temperature range (℃)20 ~ 90
      Viscosity range ν (mm2/s)15 ~ 380
      Maximum permissible degree of contamination of the pressure fluid cleanliness class to ISO 4406 (C)Class 20/18/15, we therefore recommend a filter with a minimum retention rate of β10 ≥ 75


      Application Industry

      Be mainly used in Port MachineryApplications